Microphone cord termination, This is the correct way. don't do it this way – Lectrosonics UM500 User Manual
Page 10

UM500
MICROPHONE CORD TERMINATION
Caution
When wiring the connector, do not use the connector body for any electrical connections. A common mistake is to use the
connector body as an audio ground. The connector body is already used as an RF ground on VHF models and no other use
is permitted.
1
2
3
4
5
VIEW FROM SOLDER
SIDE OF PINS
0.3"
0.15"
Heatshrink
Tubing
TA5F Connector Assembly
Mic Cord Stripping Instructions
Caution!
Do not allow the shield wire to touch any
metal part of the connector shell.
The shield wire is the antenna on VHF
models and poor operating range will result.
Shield Wire
Crimp
Tabs
Rubber
Insulation
Crimp
Tabs
Rubber
Insulation
This is the correct way.
Don't do it this way!
Note
This termination is required on VHF transmitters and will still work fine on UHF transmitters.
LECTROSONICS, INC.
10
- HH (16 pages)
- HM (20 pages)
- LMa (20 pages)
- MM400c (20 pages)
- SM Silver Paste (1 page)
- SMQV (28 pages)
- UM400a (20 pages)
- WM - Manual (24 pages)
- WM - Quick Start Guide (8 pages)
- UT700 (36 pages)
- UT195 (12 pages)
- H187 (10 pages)
- M175 (8 pages)
- T4 (16 pages)
- Octopack (20 pages)
- Quadpack (8 pages)
- UMC16b (8 pages)
- UMCWB (12 pages)
- H175DC (12 pages)
- H185 (11 pages)
- IM (16 pages)
- LM3 (6 pages)
- M170 (13 pages)
- M185 (12 pages)
- M187 (14 pages)
- MM200 - Manual (14 pages)
- MM200 - QSG (1 page)
- MM400 - Manual (14 pages)
- MM400 - QSG (1 page)
- MM400a - Manual (16 pages)
- MM400b (20 pages)
- REFUM (2 pages)
- SM (20 pages)
- SMa (24 pages)
- SMD (20 pages)
- SMDa (24 pages)
- T187 (12 pages)
- T195 (12 pages)
- T5 (12 pages)
- UH100 (10 pages)
- UH110 (10 pages)
- UH190 (10 pages)
- UH195 (10 pages)
- UH200 (10 pages)
- UH200c (10 pages)