Remove battery when it becomes fully charged

Charger output voltage must be turned down after battery is removed

At finish of charge, turn main power switch "Off" to conserve energy

When a battery is fully charged, it must be removed from the charging circuit. If it is not, it may be damaged by over charging.

END OF CHARGE:

Discontinue charge when three successive hydrometer readings taken at half hour intervals fail to show an increase in specific gravity, or when
battery begins to gas excessively or when temperature of electrolyte reaches approximately 120

EF. If a battery is sealed and these determinations

cannot be made, see manufacturer's instructions for charging.

WIRING DIAGRAM

MODEL 6080A PARTS LIST

605675 - Switch w/knob (1)
610172 - Switch - Rocker
605616 - Ammeter
605206 - AC Cord
610098 - DC Cable set
610117 - Circuit Breaker
610090 - Rectifier
610088 - Transformer

610057 - Handle (optional accessory)
610072 - Side panels (1 pair)
610075 - Top panel
610076 - Base
610082 - Back panel
610083 - Front panel
6074 - Jumper leads (set of 5)