Laurel Electronics Laureate Quadrature Encoder Position & Rate Meter User Manual
Page 2
LAUREL
ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA • Tel 714-434-6131 • www.laurels.com 2
Specifications
Display
Readout
Display Range
Zero Adjust
Span Adjust
Indicators
6 LED digits, 7-segment, 14.2 mm (.56"), red or green LED
-999999 to +999999, XXXXEX notation beyond 999999
-999999 to +999999
0 to 999999
Four LED lamps
Inputs
Type
Transitions Monitored
Max Pulse Rate
Position Error
Differential high threshold
Differential low threshold
Differential common mode
Single-ended high voltage
Single-ended low voltage
Input Resistance, typ.
Differential or single-ended quadrature
x1, x2 or x4
250 kHz at x1, 125 kHz at x2, 62.5 kHz at x4
No error contributed by meter
+200 mV
-200 mV
± 7V
2.5V to 10V
-1V to +1V
17 kOhm
Quadrature Position Mode
Zero Adjust
Span Adjust
-999999 to +999999
0 to 999999
Quadrature Rate Mode
Conversion Technique
Conversion Time
Gate time
Time Before Zero Output
Output & Display Update
Time Base Accuracy
Inverse period
Gate time + 30 ms + 0-2 signal periods
Selectable 10 ms to 199.99 s
Selectable 10 ms to 199.99 s
Same as conversion time
Calibrated to ±2 ppm
Power
Voltage, standard
Voltage, optional
Frequency
Power Isolation
85-264 Vac or 90-300 Vdc (DC operation not UL approved)
12-32 Vac or 10-48 Vdc
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test
Excitation Output (standard)
5 Vdc
10 Vdc
24 Vdc
Output Isolation
5 Vdc ± 5%, 100 mA
10 Vdc ± 5%, 120 mA
24 Vdc ± 5%, 50 mA
50 Vdc to meter ground
Analog Output (optional)
Output Levels
Current compliance
Voltage compliance
Scaling
Resolution
Isolation
4-20 mA, 0-20 mA, 0-10V, -10 to +10V (single-output option)
4-20 mA, 0-20 mA, 0-10V (dual-output option)
2 mA at 10V ( > 5 kΩ load)
12V at 20 mA ( < 600Ω load)
Zero and full scale adjustable from -99999 to +99999
16 bits (0.0015% of full scale)
250V rms working, 2.3 kV rms per 1 min test
(dual analog outputs share the same ground)
Relay Outputs (optional)
Relay Types
Current Ratings
Output common
Isolation
2 Form C contact relays or 4 Form A contact relays (NO)
2 or 4 Form A, AC/DC solid state relays (NO)
8A at 250 Vac or 24 Vdc for contact relays
120 mA at 140 Vac or 180 Vdc for solid state relays
Isolated commons for dual relays or each pair of quad relays
250V rms working, 2.3 kV rms per 1 min test