- 31 -

Over-voltage protection .................................................................................................... 125 Vac
Open sensor indication ..............................................0 mA or > 20 mA output, jumper selectable

Type

Range

Conformity Error

J

-210 to 760°C

-347to 1400°F

0.09°C

0.16°F

K

-244 to 1372°C

-408to 2501°F

0.10°C

0.17°F

T

0 to 400°C

-257 to 0°C

32 to 752°F

-430 to 32°F

0.03°C
0.20°C

0.05°F
0.36°F

E

-240 to 1000°C

-400 to 1830°F

0.18°C

0.32°F

N

-245 to 1300°C

-410 to 2370°F

0.10°C

0.17°F

S

-46 to +68°C

-51 to +213°F

0.12°C

0.22°F

R

-45 to 1768°C

-49 to 3214°F

0.17°C

0.31°F

Resistance Input

Range

Resolution

Excitation

Input Error

0-20.000 Ω

0-200.00 Ω
0-2000.0 Ω

0-20000 Ω

0-200.00 kΩ

0-2.0000 MΩ*

1 mΩ

10 mΩ

100 mΩ

1 Ω

10 Ω

100 Ω

5 mA

500 µA

50 µA

5 µA

500 nA
500 nA

0.01% of range

± 2 cts

* Factory special fixed range

Load connection: .....................................................................................................2, 3 or 4 wire
Span tempco.............................................................................................. ±0.003% of reading/ºC
Over-voltage protection .................................................................................................... 125 Vac
Open sensor indication ..............................................0 mA or > 20 mA output, jumper selectable