beautypg.com

Laurel Electronics LTE: Ethernet & 4-20 mA Transmitter for Load Cell & Microvolt Signals User Manual

Page 4

background image

LAUREL

ELECTRONICS INC.

, 3183-G Airway Ave., Costa Mesa, CA 92626, USA • Tel 714-434-6131 • www.laurels.com 4

Load Cell Transmitter Connections

In 4-wire connection, the excitation and sense lines
are tied together. The transmitter can make ratiometric
corrections for supply voltage variations, but does not
compensate for variations in lead resistance. This
connection is often used with short cable runs.

In 6-wire connection, the sense lines are separate from
the excitation lines, thereby eliminating effects due to
variations in lead resistance. This allows long cable runs
in outdoor environments with temperature extremes.

For large scales, up to four 350 ohm load cells in paral-
lel can be powered by a single Laureate transmitter at
10V, 120 mA excitation. The excitation and sense points
of the four bridges are connected in parallel through a
summing box.

Ordering Guide

Create a model a model number in this format: LTE20WM

Transmitter Type LTE Laureate 4-20 mA & Ethernet Transmitter

2 Standard Main Board
4
Extended Main Board

Main Board

Note: Extended allows custom curve linearization and rate from successive readings.

Power

0 Isolated 85-264 Vac
1
Isolated 12-32 Vac or 10-48 Vdc
2 Power over Ethernet (PoE)

Signal Input

WM1 Load Cell (4- or 6-wire ratio) with custom Scaling. Specify min input, min

output; max input, max output