41

The exclusive Fire Suppression System (F.S.S.) will extinguish fires that may start in the drying
basket (tumbler). A series of sensors positioned throughout the basket (tumbler) and interfaced
with the microprocessor will trigger the F.S.S. water jet(s) to quickly extinguish the flames. The
water jet(s) remain on for 2 minutes and will automatically activate again if a fire condition remains
or reignites. While the water jet(s) are activated, the basket (tumbler) will jog to move the water
throughout the load. The microprocessor will display that the system was activated and will continue
to display until the dryer is attended to.

We have tried to make this manual as complete as possible and hope you will find it useful. ADC
reserves the right to make changes from time to time, without notice or obligation, in prices,
specifications, colors, and material, and to change or discontinue models.

SECTION XI

FIRE SUPPRESSION SYSTEM (F.S.S.)

F.S.S. In Action