beautypg.com

Ii - performances – Continental Industrie Model - 500 User Manual

Page 4

background image

Values, dimensions and reference in this brochure are approximate and intended as guide only, not for construction and are subject to change without notice

DETAILED ENGINEERING DESCRIPTION - CONTINENTAL INDUSTRIE

DEB500EN – 04/2010

4/4

13.0 Recommended maximum allowable piping forces and moments on blower

connections

13.1 Inlet flange

FX = 900 KG

FY = 225 Kg

FZ = 180 Kg

MX = 135 kgm

MY = 67 kgm

MZ = 67 kgm

13.2 Outlet flange

FX = 80 KG

FY = 200 Kg

FZ = 160 Kg

MX = 120 kgm

MY = 60 kgm

MZ = 60 kgm


where :
F = force

M = moment

X = Axial - parallel to rotor centre line
Y = Vertical
Z = Horizontal - normal to rotor centre line.

14.0 Vibration and noise

Vibration tolerance : 4,5 mm/s RMS

Vibration shall not exceed 4,5 mm/s RMS when measured in the vertical plane at the
bearing housings with the blower operating at the design speed.

Sound level : please refer to the calculation data sheet

II - PERFORMANCES

1.

All tests if required are in conformity with ASME Power Test Code.

2.

For constant speed blowers:

- The head shall be within the range of 100% - 105% of the normal head at design capacity,

- The horsepower based on measured head shall not exceed 107% of the value at the specified

normal operating point.

3.

For variable speed machines:

- through the rotational speed, the head shall be adjusted as close as possible to the design point,

with zero negative tolerance,

- the horsepower at that point shall not exceed 104% of the predicted shaft power value.