beautypg.com

Product parameters – Cleveland Motion Controls WebPro Intermediate Tension Controller MWP-12663 REV BA User Manual

Page 16

background image

AO-70174

16

Revision BA

WebPro Intermediate Tension Controller

Possible error messages:

Calibration has failed. Either the speed was much too low for accurate
calibration, or the tachos and/or encoders are not operating correctly.


Press the SET UP key to return to the Commissioning menu

Calibration aborted.


This is shown if the SET UP key is pressed. The Controller will return to the Commissioning Menu screen.

Tension must be calibrated before speed.
Select Calibrate tension from the menu.

The controller has not been calibrated or the settings are no longer
valid. Press any key to continue.

Product Parameters

The default is Product Number 1.

Product # Parameters

(SET UP = cancel)

Length outputs

Disabled, Enabled

Preceding length

( if a line encoder is available )

Full length

( if a line encoder is available )

PI stability setting *
Maximum trim

( Output trim only - No )


An asterisk * indicates that a further menu will open if this item is selected.

If an encoder is available enable the Length Outputs and set the Preceding Length and Full Length.
The procedure for the PI stability settings is explained in Controller Tuning, below.