45

SECTION VII

REVERSING TIMER SPIN/DWELL ADJUSTMENTS

Timer models have an electronic reversing timer in the electrical service box which is located in the upper left
rear area of the dryer.

Both the Dwell (stop) Time and the basket (tumbler) Spin Time are adjustable by mode selection switches
located on the electronic timer (as noted in the illustration below).

TIMING LEGEND

SPIN TIME

Switch Postion Number

1

2

3

4

5

Time in Seconds

*

30

60

90

120

150

DWELL (Stop) TIME

Switch Postion Number

1

2

3

4

5

Time in Seconds

*

5

6

8

10

12

* Values shown are +/- 1 second.