beautypg.com

Mlg-78 (gas) mls-78 (steam) – American Dryer Corp. ML-78 User Manual

Page 24

background image

20

2. Electrical Service Specifications

IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is

affixed to the back of the dryer, at the upper right hand corner. In the case of

208 VAC or 240 VAC, the supply voltage must match the electric service

specifications of the data label exactly.

IMPORTANT: The wire size must be properly sized to handle the related current.

WARNING: 208 VAC and 240 VAC ARE NOT THE SAME. Any damage done to dryer

components due to improper voltage connections will automatically VOID THE

WARRANTY.

NOTE: For electrically heated models, contact the factory for electrical service specifications.

NOTE: ADC reserves the right to make changes in specifications at any time, without notice or

obligation.

MLG-78 (Gas)

MLS-78 (Steam)

E

LECTRIC

S

ERVICE

S

PECIFICATIONS

(

PER DRYER

)

IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTE:

A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker

size according to appliance amp draw rating and type of breaker used.

C. Circuit breakers for 3-phase dryers must be 3-pole type.

SERVICE

VOLTAGE

PHASE

WIRE

SERVICE

APPROX.

AMP

DRAW

MINIMUM

WIRE SIZE

FUSING

CIRCUIT

BREAKER

Dual Element

Time Delay

120 60 Hz

2

13

#10

20

25

208 60 Hz

2

8

#14

12

15

208 60 Hz

3

5

#14

8

15

240 50/60 Hz

2

7

#14

10

15

240 50/60 Hz

3

5

#14

8

15

380-400 50 Hz

3

3

#14

5

15

416 50 Hz

3

3

#14

5

15

460 60 Hz

3

3

#14

5

15