Base installation – King Technology FROG Leap Model 7800 User Manual
Page 15

15
TOOLS NEEDED
Screwdriver
Pipe Wrench
Materials Needed
Pipe Thread
Tape
or Sealant
Two Hose Adapters
1 1/2” X 1 1/2” X 1 1/4”
Two Sections
of 1 1/2” Flex Hose
(one provided with filter)
Two
Hose
Clamps
Recommended
Corrosion Resistant
Check Valve
4-8 psi Back Pressure
To avoid over or under chlorination,
replace eye ball fittings in the return
jets to a smaller or larger size to
adjust back pressure.
10 X 1 1/4” Phillips Pan
Head Screws with Washers
Apply pipe thread tape or
sealant to the threaded end of
both hose adapters.
1.
The FROG Leap Infuzer™ should always be
installed between the filter and pool (or between
heater and pool if applicable).
Base Installation
Screw adapters into each end of FROG
Leap Infuzer™. Hand tighten. Finish
tightening by turning 1 to 2 revolutions
with wrench. DO NOT OVER TIGHTEN.
2.
Attach the filter section of flex hose to one hose adapter
and the return section of flex hose to the other hose
adapter with clamps and tighten with screwdriver. Bi-flow
valve design allows water flow in either direction.
3.
If using a FROG Leap Torpedo Pac™ installing a
corrosion resistant check valve is recommended.
4.
For better stability,
FROG Leap Infuzer™
may be mounted on
a base using Phillips
pan head screws.
One in front and two
in back.
5.
TO POOL
PUMP
FILTER
• Never install FROG Leap
Infuzer™ before the heater.
• Any additional sanitizing
equipment that is installed with
FROG Leap Infuzer™ must be
installed after FROG Leap Infuzer™
(never before) on the return line
to the pool.
HOSE
CLAMP
HOSE
ADAPTER
HOSE
CLAMP
HOSE
ADAPTER
TO POOL
1 1/2" OR 1 1/4"
FLEX HOSE
1 1/2"
X
1 1/2"
X
1 1/4"
HOSE ADAPTER
HOSE
CLAMP
FILTER &
PUMP
Option
1 1/2” Male Adapter
(slip x MPT)
or
2” Female Adapter
(slip x FPT)
When installing with hard
PVC pipe, use either a female
adapter on the outside port
threads or a male adapter on
the inside port threads.