beautypg.com

Hydrotech Classic Series Stenner Basic Service Manual User Manual

Page 22

background image

21

Tube fittings pulling out of the tube

• Pulling excessively on the tube fitting when installing a

replacement tube. Allow rollers to stretch tube into
position and follow tube replacement instructions.

• Pre-stretching the tube before replacement.

Normal tube failures

• Pin hole at discharge side; tube will leak.

• Breakage at the suction side.

• Fatigued, no longer completely compresses, no rupture

evident, doesn’t pump.

The above conditions are usually indications that the tube has
reached the end of its service life. If all other conditions/wear
have been checked and corrected, determine maintenance
schedule.

NOTE

Additional information

Due to wear, the used tube will have stretched and
will be longer than the new tube.

NOTE

Additional information

Tube fitting flange cracks are normal on the
discharge tube fitting. They do not indicate a
failure or defect.

Continued...