Parts breakdown — buv models, Performance data sheet – Hydrotech PURA ABuv 6_8_12 User Manual
Page 11
![background image](/manuals/332402/11/background.png)
11
Parts Breakdown — Buv Models
Item #
Part Ref
Description
Qty
For UV Model
89573
2
Quartz Sleeve, Buv-6
1
Buv-6
89574
2
Quartz Sleeve, Buv-8
1
Buv-8
89575
2
Quartz Sleeve, Buv-12
1
Buv-12
89577
3
Chamber Nut, Lamp Entry, Threaded
2
All Models
89578
5
O-Ring
2
All Models
89584
6
Countdown Timer, c/w Bracket
1
All Models
89579
7
Clip
2
All Models
89581
8
Flow Control, 6 GPM, 1/2” NPT
1
Buv-6
89582
8
Flow Control, 8 GPM, 3/4” NPT
1
Buv-8
89583
8
Flow Control, 12 GPM, 1” NPT
1
Buv-12
89570
9
Lamp, UV, Buv-6
1
Buv-6
89571
9
Lamp, UV, Buv-8
1
Buv-8
89572
9
Lamp, UV, Buv-12
1
Buv-12
89580
10
Ballast
1
All Models
89576
11
Strain relief
1
All Models
89585
12
Chamber Nut, c/w Stopper Bottom
1
All Models
Item #
8880
8881
8882
Model #
Buv-6
Buv-8
Buv-12
Supplier Item #
GN-6
GN-8
GN-12
NSF Rated Flow Rate @ 16mJ/
cm2 @ 70% UVT - usgpm (l/min)
5.5 (20.79)
7.8 (29.48)
12 (45.36)
Inlet and Outlet Size NPT
1/2”
3/4”
1”
Operating Pressure psi (kpa)
10-100 psi (69-689 kPa)
Operating Temperature Range
36 to 104° F (2 to 40° C)
Electrical
100-240V - 50/60Hz
Performance Data Sheet
While testing was performed under standard laboratory conditions, actual performance may vary.
This Class B system or component conforms to NSF/ANSI 55 for the supplemental bactericidal treatment disinfected public
drinking water or other drinking water that has been tested and deemed acceptable for human consumption by the state or local
health agency having jurisdiction. The system is only designed to reduce normally occuring non-pathogenic nuisance microorgan-
isms. Class B systems are not intended for treatment of contaminated water.
The system and installation shall comply with applicable state and local regulations
Lamp life: 8000-9000 hours of operation approximate
12 months of continuous service
General installation conditions and needs: Avoid touch-
ing the sides of the quartz sleeve and lamp, handle by
the ends only. Ultraviolet lamp and quartz sleeve are
easily damaged.
General operation and maintenance: Quartz sleeve is
to be cleaned every 6-12 months and to be replaced
every 24 months. UV lamp is to be replaced every year.
1
1
9
3
11
10
2
8
5
12
7
6
5
4
5
System Tested and Certified by
NSF International against NSF/
ANSI Standard 55 for Disinfection
Performance, Class B