Parts Breakdown — Buv Models

Item #

Part Ref

Description

Qty

For UV Model

89573

2

Quartz Sleeve, Buv-6

1

Buv-6

89574

2

Quartz Sleeve, Buv-8

1

Buv-8

89575

2

Quartz Sleeve, Buv-12

1

Buv-12

89577

3

Chamber Nut, Lamp Entry, Threaded

2

All Models

89578

5

O-Ring

2

All Models

89584

6

Countdown Timer, c/w Bracket

1

All Models

89579

7

Clip

2

All Models

89581

8

Flow Control, 6 GPM, 1/2” NPT

1

Buv-6

89582

8

Flow Control, 8 GPM, 3/4” NPT

1

Buv-8

89583

8

Flow Control, 12 GPM, 1” NPT

1

Buv-12

89570

9

Lamp, UV, Buv-6

1

Buv-6

89571

9

Lamp, UV, Buv-8

1

Buv-8

89572

9

Lamp, UV, Buv-12

1

Buv-12

89580

10

Ballast

1

All Models

89576

11

Strain relief

1

All Models

89585

12

Chamber Nut, c/w Stopper Bottom

1

All Models

Item #

8880

8881

8882

Model #

Buv-6

Buv-8

Buv-12

Supplier Item #

GN-6

GN-8

GN-12

NSF Rated Flow Rate @ 16mJ/

cm2 @ 70% UVT - usgpm (l/min)

5.5 (20.79)

7.8 (29.48)

12 (45.36)

Inlet and Outlet Size NPT

1/2”

3/4”

1”

Operating Pressure psi (kpa)

10-100 psi (69-689 kPa)

Operating Temperature Range

36 to 104° F (2 to 40° C)

Electrical

100-240V - 50/60Hz

Performance Data Sheet

While testing was performed under standard laboratory conditions, actual performance may vary.
This Class B system or component conforms to NSF/ANSI 55 for the supplemental bactericidal treatment disinfected public

drinking water or other drinking water that has been tested and deemed acceptable for human consumption by the state or local

health agency having jurisdiction. The system is only designed to reduce normally occuring non-pathogenic nuisance microorgan-

isms. Class B systems are not intended for treatment of contaminated water.
The system and installation shall comply with applicable state and local regulations

Lamp life: 8000-9000 hours of operation approximate

12 months of continuous service

General installation conditions and needs: Avoid touch-

ing the sides of the quartz sleeve and lamp, handle by

the ends only. Ultraviolet lamp and quartz sleeve are

easily damaged.

General operation and maintenance: Quartz sleeve is

to be cleaned every 6-12 months and to be replaced

every 24 months. UV lamp is to be replaced every year.

1

1

9

3

11

10

2

8

5

12

7

6

5

4

5

System Tested and Certified by

NSF International against NSF/

ANSI Standard 55 for Disinfection

Performance, Class B