Problem: Combination Softener unit appear to be causing a high pressure drop in home water system.

1. Pressure drop may be due other factors.

Confirm pressure loss is due to the unit, and
not the result of distribution or well pump problem.

Confirm pressure loss is due to unit by
checking flow while in BYPASS mode.

Check that flow demand is not exceeding rated
flow rate of Combination Softener unit. These units
are supplied with a SERVICE LINE FLOW
CONTROL to ensure maximum effectiveness is
maintained. Attempting to exceed this flow control
rating will result in a pressure drop. Combination
Softener unit should be increased in size to
compensate for larger demand.

NOTE: Do not remove this FLOW CONTROL
from valve outlet. It will likely result in a
decrease in Combination Softener unit
performance.

2. Pressure loss may be due to fouling from

See troubleshooting notes above on dealing with

Organics, Iron or Calcium Carbonate.

fouling problems.

3. Pressure loss may be due to Resin Media being

Try manually regenerating the unit and extending

plugged with Silt and Turbidity.

the backwash by unplugging unit during the first
cycle that begins to send water to the drain.
Monitor water to the drain and watch for dirt and
silt. If present, continue this backwash cycle until
water runs clear then plug unit and allow valve
to finish regeneration normally.

Install multi-media filter or 5 micron cartridge filter
ahead of the unit to remove Silt and Turbidity.

Problem: Combination softener unit appears to be removing most of the colour in the water, but some still
passes through.

1. Raw water may be partially slipping past Combination

Check to see that SERVICE LINE FLOW

Softener unit or the Organics (Tannins) not being

CONTROL is in place on the valve outlet.

removed may be impervious to the resin media in the

Flowrates higher than recommended through the

Combination Softener unit.

unit may be causing some leakage of colour.

Check to see that BYPASS valve is not partially
open and bleeding some raw water to distribution
lines.

Check that pipelines after the unit are not lined
with organics that are slowly being stripped away.
Lines may require flushing.

If all equipment and distribution sources of problem
have been eliminated, consult your water treatment
dealer, who may try to “polish” the remaining colour
after the the unit with an ACTIVATED CARBON
filter or cartridges or other treatment method.