Hydrotech 7000 SXT Valve Water Softener User Manual
Page 8
7
User Programming Mode Options
Abbreviation
Parameter
Description
DO
Day Override
The timer’s day override setting
THIS IS AN OPTION ONLY. PLEASE DO NOT ADjUST
BEFORE CONSULTING AN AUTHORIzED DEALER.
RT
Regeneration Time
The time of day that the system will regenerate (meter delayed,
timeclock, and day-of-week systems)
H
Feed Water Hardness
The hardness of the inlet water - used to calculate system
capacity for metered systems
RC
Reserve Capacity
The fixed reserve capacity
CD
Current Day
The current day of week
NOTES:
Some items may not be shown depending on timer configuration.
The timer will discard any changes and exit User Mode if any button is not pressed for sixty seconds.
User Programming Mode Steps
1. Press the Up and Down buttons for five seconds while in
service, and the time of day is NOT set to 12:01 PM.
2. Use this display to adjust the Day Override. This option
setting is identified by “DO” in the upper left hand corner
of the screen.
THIS IS AN OPTION ONLY. PLEASE DO NOT ADjUST
BEFORE CONSULTING AN AUTHORIzED DEALER.
3. Press the Extra Cycle button. Use this display to adjust
the Regeneration Time. This option setting is identified
by “RT” in the upper left hand corner of the screen.
4. Press the Extra Cycle button. Use this display to adjust the Feed Water Hardness. This option setting is identified by
“FH” in the upper left hand corner of the screen.
5. Press the Extra Cycle button. Use this display to adjust the Fixed Reserve Capacity. This option setting is identified
by “RC” in the upper left-hand corner of the screen.
75 gallons X # of people in the house = RC
6. Press the Extra Cycle button to end User Programming Mode.
# of People
RC
1
75
2
150
3
225