Maintenance Instructions

Checking the Salt Level

Check the salt level monthly. Remove the lid from the cabinet or brine tank, make sure salt level is always above the

brine level (you should not be able to see water).

Adding Salt

Use only clean salt labeled for water conditioner use, such as crystal, pellet, nugget, button or solar.

The use of rock salt is discouraged because it contains insoluble silt and sand which build up in the brine tank and can

cause problems with the system’s operation.

Add the salt directly to the tank, filling no higher than the top of the brine well.

Caution

Liquid brine will irritate eyes, skin and open wounds - gently wash exposed area with fresh water. Keep children away

from your water conditioner.

Bridging (Figure 6)

Humidity or the wrong type of salt may create a cavity between the water and the salt.

This action, known as “bridging”, prevents the brine solution from being made, leading to

your water supply being hard.

If you suspect salt bridging, carefully pound on the outside of the plastic brine tank

or pour some warm water over the salt to break up the bridge. This should always

be followed up by allowing the unit to use up any remaining salt and then thoroughly

cleaning out the brine tank. Allow four hours to produce a brine solution, then manually

regenerate the softener.

Care of Your Softener

To retain the attractive appearance of your new water softener, clean occasionally with

a mild soap solution. Do not use abrasive cleaners, ammonia or solvents. Never subject

your softener to freezing or to temperatures above 110

°

F (43°C).

Cleaning the Injector Assembly (Figure 7)

Sediment, salt and silt will restrict or clog the injector. A clean water

supply and pure salt will prevent this from happening.
The injector assembly is located on the right side of the control valve.

This assembly is easy to clean.
Shut off the water supply to your softener and reduce the pressure by

opening a cold soft water faucet. Using a screwdriver, remove the two

screws holding the injector cover to the control valve body. Carefully

remove the assembly and disassemble as shown in Figure 7. The

injector orifice is removed from the valve body by carefully turning

it out with a screwdriver. Remove the injector throat the same way.

Carefully flush all parts including the screen. Use a mild acid such as

vinegar or Pro-Rust Out to clean the small holes in the orifice and throat.
Reassemble using the reverse procedure.

Resin Cleaner

An approved resin cleaner MUST be used on a regular basis if your water supply contains iron. The amount of resin

cleaner and frequency of use is determined by the quantity of iron in your water (consult your local representative or

follow the directions on the resin cleaner package).

INjECTOR BODY

INjECTOR THROAT

INjECTOR NOzzLE

“O” RING

INjECTOR COVER

INjECTOR SCREEN

SCREW

Figure 7

Figure 6