Performance and specifications, How your water conditioner works, Figure 1 – Hydrotech 6700 XTR Valve Upflow Automatic Water Softeners Operation Manual User Manual
Page 3
![background image](/manuals/332339/3/background.png)
1
Performance and Specifications
Upflow
Capacity at Various Salt Dosages
Service Flow
Backwash
Resin
Mineral
Brine
Brine Tank
Shipping
Metered
grains
Rate
(2)
Flow Rate
Volume
Tank Size
(3)
Tank Size
(3)
Salt Capacity
Weight
Model
@15lb/cf
@10lb/cf
(1)
@6lb/cf
@3lb/cf
USGPM
USGPM
cu. ft.
inches
inches
Lbs.
Lbs.
6700MIU-844-75
22,500
18,000
12,750
9,750
8
1.5
0.75
8 x 44
18 x 33
335
70
6700MIU-948-100
30,000
24,000
17,000
13,000
10
2.0
1.00
9 x 48
18 x 33
335
85
6700MIU-1047-125
37,500
30,000
21,250
16,250
12
2.4
1.25
10 x 47
18 x 33
335
110
6700MIU-1054-150
45,000
36,000
25,500
19,500
12
2.4
1.50
10 x 54
18 x 33
335
125
6700MIU-1252-200
60,000
48,000
34,000
26,000
13
3.5
2.00
12 x 52
18 x 33
335
150
6700MIU-1450-250
75,000
60,000
42,500
32,500
13
5.0
2.50
14 x 50
21 x 36
335
190
Operating Temperature Range: 34° to 110°F (1° to 43°C).
Operating Pressure Range: 20 to 120 psi (1.37 to 8.27 bar).
Electrical: 24V/60Hz with a supplied 120V/60Hz Wall Mount CSA Approved Transformer
Caution: These products are not intended to be used to treat water that is microbiologically unsafe or
of unknown quality without adequate disinfection before or after the system.
NOTES:
(1)
10lb/cu.ft. salt dosage is the standard factory setting.
(2)
The Service Flow Rate given will not exceed a pressure drop of 15psi.
(3)
Dimensions of cylindrical tanks shown are diameter (or width) x height. Cabinets shown as
length x width x height.
• The manufacturer reserves the right to make product improvements which may deviate from the
specifications and descriptions shown above, without obligation to change previously manufactured
products or to note the change.
How Your Water Conditioner Works
Hard water enters your home through the main supply line, enters your water conditioner, and passes down through a bed
of ion exchange resin which softens the water. An ion exchange process takes place in which the resin beads capture and
hold calcium and magnesium, the hardness impurities, while the water takes on sodium ions. The soft water then flows up
and into your household water line.
On the days your water conditioner regenerates, the resin is automatically recharged by passing a brine solution (salt
water) through it. This reverses the ion exchange process, charging the resin with sodium and freeing the hardness
minerals. These minerals and the brine solution are then flushed away through the drain line followed by a rapid rinse.
The resin bed is again ready to soften water.
Figure 1