beautypg.com

Performance and specifications, How your 5600 sxt downflow water conditioner works, Control operation during regeneration – Hydrotech 5600 SXT Valve Downflow Automatic Water Softeners Operation Manual User Manual

Page 2

background image

1

Performance and Specifications

Meter

Capacity at Various Salt Dosages

Service Flow

Backwash

Resin

Mineral

Brine

Brine Tank

Shipping

Initiated

grains

Rate

(2)

Flow Rate

Volume

Tank Size

(3)

Tank Size

(3)

Salt Capacity

Weight

Model

@15lb/cf

@10lb/cf

(1)

@6lb/cf

@3lb/cf

USGPM

USGPM

cu. ft.

inches

inches

Lbs.

Lbs.

Twin Tank Models
5600SXTM-835-50

15,000

12,000

8,500

6,500

6

1.5

0.50

8 x 35

18 x 33

335

65

5600SXTM-844-75

22,500

18,000

12,750

9,750

8

1.5

0.75

8 x 44

18 x 33

335

70

5600SXTM-948-100

30,000

24,000

17,000

13,000

10

2.0

1.00

9 x 48

18 x 33

335

85

5600SXTM-1035-100

30,000

24,000

17,000

13,000

10

2.4

1.00

10 x35

18 x 33

335

90

5600SXTM-1047-125

37,500

30,000

21,250

16,250

12

2.4

1.25

10 x 47

18 x 33

335

110

5600SXTM-1054-150

45,000

36,000

25,500

19,500

12

2.4

1.50

10 x 54

18 x 33

335

125

5600SXTM-1252-200

60,000

48,000

34,000

26,000

13

3.5

2.00

12 x 52

18 x 33

335

150

5600SXTM-1450-250

75,000

60,000

42,500

32,500

13

5.0

2.50

14 x 50

21 x 36

355

190

Cabinet Models
CAB5600SXTM-835-50

15,000

12,000

8,500

6,500

6

1.5

0.50

8 x 35

21 x 13 x 44

315

65

CAB5600SXTM-1035-100

30,000

24,000

17,000

13,000

10

2.4

1.00

10 x 35

21 x 13 x 44

300

90

ADDITIONAL INFORMATION: Operating Temperature Range = 34° to 110°F (1° to 43°C). Operating Pressure Range = 20 to 120 psi (1.37 to 8.27 bar). The manufacturer reserves the right to make product
improvements which may deviate from the specifications and descriptions shown above, without obligation to change previously manufactured products or to note the change.
CAUTION: These products are not intended to be used to treat water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
NOTES:

(1)

10lb/cu.ft. salt dosage is the standard factory setting.

(2)

The Service Flow Rate given will not exceed a pressure drop of 15psi.

(3)

Dimensions of cylindrical tanks shown are diameter (or width) x

height. Cabinets shown as length x width x height.

How Your 5600 SXT Downflow Water Conditioner Works

Hard water enters your home through the main supply line, enters the softener and passes down through a resin mineral
bed which softens the water. An ion exchange process takes place in which the resin beads capture and hold calcium and
magnesium, the hardness minerals, while the water takes on sodium ions. The soft water then flows into your household
water line.

In normal operation, the Time of Day display will alternate being viewed with the Volume Remaining display. This display
will be in gallons, liters or cubic meters. As treated water is used, the Volume Remaining display will count down from a
maximum value to zero or (---). Once this occurs, a regeneration cycle will be initiated at the Set Regeneration Time. Water
flow through the valve is indicated by the Flow Indicator that will flash in direct relationship to flow rate.

Example

833 Gallons of Treated
Water Remaining

0 Gallons of Treated
Water Remaining

Control Operation During Regeneration

In regeneration, the control will display a special regeneration display. In this display, the control will show the current
regeneration step number the valve is advancing to or has reached and the time remaining in that step. The step
number displayed will flash until the valve has completed driving into this regeneration step position. Once all
regeneration steps have been completed, the valve will return to Service and resume normal operation.

Example

Less than 6 minutes
remaining in Regen
Step Rapid Rinse

Pushing the Extra Cycle Button during a regeneration cycle will immediately advance the valve to the next cycle step
position and resume normal step timing.

5

PM Indicator

PM Indicator

Flow Indicator
(Flashing with water flow)

Flow Indicator