beautypg.com

Trouble shooting guide – Hydrotech 5600 SXT Valve Downflow Automatic Water Softeners Operation Manual User Manual

Page 11

background image

Trouble Shooting Guide

1.

CONDITIONER DELIVERS HARD WATER
Bypass valve is open

Close bypass valve

No salt in brine tank

Add salt to brine tank and maintain salt level above water level

Injector or screen plugged

Replace injectors and screen

Insufficient water flowing into brine tank

Check brine tank fill time and clean brine line flow tank control if plugged

Hot water tank hardness

Repeated flushing of the hot water tank is required

Leak at distributor tube

Make sure distributor tube is not cracked. Check O ring and tube pilot

Internal valve leak

Replace seals and spacers and/or piston

Flow meter jammed

Remove obstruction from flow meter

Flow meter cable disconnected or not plugged

Check meter cable connection to timer and meter cap

into meter cap
Improper programming

Reprogram the control to the proper regeneration type, inlet water hardness,
capacity or flow meter size.

2.

CONDITIONER FAILS TO REGENERATE
Electrical service to unit has been interrupted

Assure permanent electrical service (check fuse, plug, chain or switch)

Timer is not operating properly

Replace timer

Defective valve drive motor

Replace drive motor

Improper programming

Check programming and reset as needed

3.

UNIT USES TOO MUCH SALT
Improper salt setting

Check salt usage and salt setting

Excessive water in brine tank

See #7

Improper programming

Check programming and reset as needed

4.

LOSS OF WATER PRESSURE
Iron build-up in line to water conditioner

Clean line to water conditioner

Iron build-up in water conditioner

Clean control and add resin cleaner to resin bed. Increase frequency
of regeneration

Inlet of control plugged due to foreign material

Remove piston and clean control

broken loose from pipes by recent work done on
plumbing system

5.

LOSS OF RESIN THROUGH DRAIN LINE
Air in water system

Assure that well system has proper air eliminator control. Check for dry well
condition.

Drain line flow control is too large

Ensure drain line flow control is sized

6.

IRON IN CONDITIONED WATER
Fouled resin bed

Check backwash, brine draw and brine tank fill. Increase frequency of
regeneration. Increase backwash time.

Iron content exceeds recommended parameters

Add iron removal filter system

7.

EXCESSIVE WATER IN BRINE TANK
Plugged drain line flow control

Clean flow control

Brine valve failure

Replace brine valve

Improper programming

Check programming and reset as needed

8.

SALT WATER IN SERVICE LINE
Plugged injector system

Clean injector and replace screen

Timer not operating properly

Replace timer

Foreign material in brine valve

Clean or replace brine valve

Foreign material in brine line flow control

Clean brine line flow control

Low water pressure

Raise water pressure

Improper programming

Check programming and reset as needed

9.

CONDITIONER FAILS TO DRAW BRINE
Drain line flow control is plugged

Clean drain line flow control

Injector is plugged

Clean or replace injectors

Injector screen is plugged

Replace screen

Line pressure is too low

Increase line pressure (line pressure must be at least 20 psi at all times)

Internal control leak

Change seals and spacers and/or piston assembly

Improper programming

Check programming and reset as needed

Timer not operating properly

Replace timer

10. CONTROL CYCLES CONTINUOUSLY

Timer not operating properly

Replace timer

Faulty microswitches and/or harness

Replace faulty microswitch or harness

Faulty cycle cam operation

Replace cycle cam or reinstall

11. DRAIN FLOWS CONTINUOUSLY

Foreign material in control

Remove piston assembly and inspect bore. Remove foreign material and check
control in various regeneration positions

Internal control leak

Replace seals and/or piston assembly

Control valve jammed in brine or backwash position Replace piston and seals and spacers
Timer motor stopped or jammed teeth

Replace timer motor and check all gears for missing teeth

Timer not operating properly

Replace timer