beautypg.com

Equipment specifications, Conditions for use, Dimensions – Hydrotech SL844-12 Scaleless POE Residential System User Manual

Page 5

background image

Equipment Specifications

Scaleless systems are complete, self-contained, loaded with media and ready to use. A simple inlet and outlet connection

is all that is required for installation. Please review operating pressures, temperatures and water chemistry limitations to

ensure compatibility.

Conditions for Use

Inlet/Outlet Connection

3/4” - 1”

Temperature

40° - 110°F

pH

6.5 to 8.5

Ferrous Iron, Max*

0.3 mg/L

Manganese, Max*

0.05 mg/L

Copper, Max*

1.3 mg/L

Water Pressure

15 min., 100 max (PSI)

* See note about Iron, Manganese and Copper on the next page.

a

b

c

e

d

Dimensions

(nominal - inches) –

SL844-12, SL948-16, SL1054-20 and SL1252-30

a

48.5

52.5

59.5

56.5

b

46

48

57

54

c

8

9

10

12

d

2.5

2.5

2.5

2.5

e

3.0

3.0

3.0

3.0

Using Scaleless with other water treatment equipment.

Due to the unique properties of Scaleless, there are some unique require-

ments for using Scaleless in conjunction with filtration or other forms of

water treatment.
1. Scaleless must be the last stage in the treatment chain. Do not install

any filters after Scaleless or before any devices for which scale preven-

tion is required. POU filters, e.g. carbon or RO are exempt from this

requirement.

2. Do not apply phosphate or any other antiscalant either before or after

Scaleless.

Item #

Model #

Tank

Media

(lbs)

Max Flow

Rate (GPM)

Frequency of Me-

dia Replacement

Connections

I/O

Bypass Replacement

Media Bed #

Dry Weight

(lbs)

Service

Weight (lbs)

7951

SL844-12 8 x 44

5

12

3 years

3/4”

Plastic

21514-5

25

97

7952

SL948-16 9 x 48

6

16

3 years

3/4”

Plastic

21514-6

29

129

7953 SL1054-20 10 x 54

8

20

3 years

1”

Plastic

21514-8

35

168

7954 SL1252-30 12 x 52

11

30

3 years

1”

Plastic

21514-11

43

235

Water should enter

from this side of the

adapter/bypass