5.0 ENVIRONMENT:
5.1 AMBIENT OPERATION TEMPERATURE
0°C to +65°C
5.2 AMBIENT OPERATION RELATIVE HUMIDITY 20% to 85%
5.3 AMBIENT STORAGE TEMPERATURE
-40°C to +70°C
5.4 AMBIENT STORAGE RELATIVE HUMIDITY
10% to 95%
6.0 CE REQUIREMENTS:
6.1 EMI
Meets FCC PART15 CLASS B
6.2 SAFETY REQUIREMENTS
Meets UL 1950, Third Edition
Meets EN 60950:1992 +A1:1993 +A2:1993 +A3:1995 +A4:1997
+A11:1997
Meets IEC 60950:1991 +A1:1992 +A2:1993 +A3:1995 +A4:1996
7.0 MTBF at 25°C =80,000 hours
8.0 DC CONNECTOR AND CASE REQUIREMENTS
8.1 BASEBOARD CONNECTOR
ATX MAIN CONNECTOR (P1)
HOUSING: P/N P20-I42002 OR EQU
TERMINAL: P/N I42002BS-2 OR EQU
115V/230V(FULL LOAD):1mS minimum
FIGURE 1
4.1 REMOTE ON/OFF CONTROL
The power supply is turn on/off by TTL signal.
Remote On/Off Signal Characteristics
4.2 AUXILIARY +5Vsb
This power supply is specifically equipped with an independent stand-by +5V
output current, 2.0A max. This output will always provide +5V except when
the AC line is cut-off.
4.3 AUTO RESTART
If the power supply's output dropped out of the regulation, which is caused by
AC line Voltage, the power supply will automatically resumed normal operation
only after the AC line voltage returns to the specified operating range.
AC-V
AC-ON
AC-OFF
PS-ON
HIGH
LOW
T1
T2
T3
T5
T4
TURN-ON
POWER GOOD
ON-RING
OFF-RING
POWER FAIL
HIGH
HOLD-UP
P.G. WAVE FORM
VB= 4.75V
+5V Wave Form
Active Low
Power Supply turn on
Active High
Power Supply turn off
PS-ON
MIN MAX
Vil input low voltage
0.8V
Lil, input low current ,Vin=0.4V
-1.6mA
Vih, input High voltage, lin=-200uA 2.0V
Vih open circuit, lin=0
5.25V
16AWG (Wire)
Signal
Pin
Pin
Signal
16AWG (Wire)
Orange
+3.3Vdc
13
1
+3.3Vdc
Orange
Blue
-12Vdc
14
2
+3.3Vdc
Orange
Black
COM
15
3
COM
Black
PS-ON
16
4
+5Vdc
Red
Black
COM
17
5
COM
Black
Black
COM
18
6
+5Vdc
Red
Black
COM
19
7
COM
Black
Empty
Empty
20
8
POK
Red
+5Vdc
21
9
+5VSB
Purple
Red
+5Vdc
22
10
Yellow
Red
+5Vdc
23
11 +12V
1
dc
Yellow
Gray (22AWG)
Green (22AWG)
+12V
1
dc
Black COM 24 12 +3.3Vdc Orange