Specifications, Operation – GeneralAire TERsus 2000 User Manual
Page 3

2
SpecIfIcatIonS
model tersus 1200:
(Capacity 1-1/2 to 3.0 tons)
MFG: GeneralAire
Model: TERSus1200
Power: 120V/60 Hz .6 Amps 49.2 Watts
Fuse: Replace only with AGC-2 fuse
Application: 3 Ton Drive Air Handler / Furnace
Max Face Velocity: 500 FPM
Max Air Flow: 1200 CFM
Service: U.V. Lamps - 1 year / Filter – 6/12 months
Replace: Only with LT016 UV lamps.
Replace: Filter with only FI018 MERV-13
U.V. Range: 254 NM (germicidal)
Catalyst: Metal Oxides 56 Sq. Feet
Weight: 23 LBS
Dimensions: 17” H x 25” W x 10” D
model tersus 2000:
(Capacity 4.0 to 5.0 tons)
MFG: GeneralAire
Model: TERSus2000
Power: 120V/60 Hz .6 Amps 49.2 Watts
Fuse: Replace only with AGC-2 fuse
Application: 5 Ton Drive Air Handler / Furnace
Max Face Velocity: 625 FPM
Max Air Flow: 2000 CFM
Service: U.V. Lamps - 1 year / Filter – 6/12 months
Replace: Only with LT016 UV lamps.
Replace: Filter with only FI016 MERV-13
U.V. Range: 254 NM (germicidal)
Catalyst: Metal Oxides 70 Sq. Feet
Weight: 26 LBS
Dimensions: 21” H x 25” W x 10” D
operatIon
The GeneralAire TERSus air purification system installs in the air-inlet side of any heating and air-conditioning
system up to five tons in size. Only operation of the air-handler fan unit is required for air purification and
sterilization to take place.
Note: The ultraviolet lamps are wired to operate continuously. This feature allows the catalyst to burn off surface
impurities, cleaning and reactivating itself during periods of non-use or no airflow. The cost of operation is less than
.07 cents per day. See operating cost section.
The GeneralAire TERSus air purification system combines three unique technologies to protect people against
indoor air pollutants. Photo catalytic technology (PCO) combined with high efficiency electrostatic MERV13
particulate filtration and germicidal ultraviolet light quickly reduces and eliminated toxic gas-phase chemicals,
lung damaging dust and airborne germs from the living environment.
Many new homes have smart programmable thermostats that allow for automatic operation of the air-handler fan
unit when there is no demand for heating or air conditioning. It is important that the GeneralAire TERSus air
purification system is operating at least 30 minutes per hour (24) hours per day to remove toxic materials from
the indoor environment.
The length of operation depends on the location of the home or office in relation to point source pollution such
as refineries, processing plants, automobile traffic and areas that produce high levels of pollen. Individuals that
are sensitive to mold spores, dust mites, chemicals or have respiratory problems such as asthma, emphysema, and
chronic allergies should extend the run time to (40) minutes or more per hour.
aIr cycLeS per Hour
(Based on 3000 sq. ft.)
Fan unit on for 10 minutes per hour
Air cycled(1) ------- times per hour
Fan unit on for 15 minutes per hour
Air cycled(1.3) ----- times per hour
Fan unit on for 20 minutes per hour
Air cycled(1.75) ---- times per hour
Fan unit on for 30 minutes per hour
Air cycled(2.62) ---- times per hour