Pump installation, Positioning the pump – BJM Pumps JX-F SERIES SIDE DISCHARGE Electric Submersible Pumps User Manual
Page 8
8
PUMP INSTALLATION
J-F & JX-F Series pumps have been evaluated for use with water or water based
solutions. Please contact the manufacturer for additional information.
Lifting:
Attach a rope or lifting chain (not included) to the handle (or lifting rings) on the top of
the pump.
Do not lift the pump by the power cable or discharge hose/piping.
Proper lifting equipment (rope/chain) must be used.
POSITIONING THE PUMP
BJM Pumps, J-F & JX-F Series pumps are designed to operate fully submerged. Data
sheets can be obtained online a
860-399-5937.
Do not run pump dry.
Pump liquid should not exceed a maximum temperature of 200°F (93°C).
Never place the pump on loose or soft ground. The pump may sink, preventing
water from reaching the impeller. Place on a solid surface or suspend the pump
with a lifting rope/chain. The J-F & JX-F Series pumps are provided with a
suction strainer to prevent large solids from clogging the impeller. Any spherical
solids which pass through the strainer should pass through the pump.
For maximum pumping capacity, use the proper size non-collapsible hose or rigid
piping. A check valve may be installed after the discharge to prevent back flow
when the pump is shut off.