BJM Pumps KZN-HYD6R User Manual
Page 10
![background image](/manuals/329664/10/background.png)
11
Install lifting bracket (1) with (2) bolts (#2).
Pour 32 ounces of clean 10w or 20w non-detergent oil (hydraulic oil) into seal chamber
and install oil plug (#29) with O ring (#30).
If equipped, install inlet and outlet pigtail hoses (#54, 55) and quick disconnect hose
couplings (#56, 57). Use a liquid or paste hydraulic sealant on pipe threads (NOT
TEFLON TAPE) and be sure pressure and return connections are installed correctly.
SEE PARTS ILLUSTRATION.
Connect hydraulic hoses from the pump to a properly sized hydraulic power unit and
test run. The pump should spin smoothly. Check to be sure there are no oil leaks and
check for proper rotation. Impeller spins clockwise when viewed from top (discharge
end) of pump.