WIRING 

Step Five 

ELECTRICAL CONNECTIONS: 
The LV41 and LV42 series feature a SPDT relay contact.  SPDT, single pole double throw allows for operation of 
both  increasing  and  decreasing  level,  depending  on  the  connections  made  between  the  terminals  of  the 
micro‐switch and the cable.  SPDT, which is a three‐conductor cable, has one lead that is common, one that is 
normally  open  (NO),  and  the  other  that  is  normally  closed  (NC).  For  the  proper  connections  of  these 
conductors please refer to the wiring diagrams below. 

NC Wiring: 

 

The Normally Closed (NC) wiring is typically used for a filling operation.  The contact will close at a low level 
and open at a high level. 

NO Wiring: 

 

The Normally Open (NO) wiring is typically used for an emptying operation.  The contact will close at a high 
level and open at a low level. 

Warning:  When making the connections described above, ensure that the maximum motor 

power does not exceed the values indicated on the level switch.  The power supply cable is 
an important part of the sump float.  Should the cable appear to be damaged, discontinue 
use immediately and proceed to replace the unit.  The terminal used must also be protected 
against accidental break.  Also, 

correctly insulate any wire not in use.

 