Ebara Self Priming Jet Pumps

JEU

Troubleshooting

(continued)

Type of Fault

The pump stops after brief periods of operation (booster set applications).

Cause

Remedy

Very small difference between

Increase the difference in pressure

maximum and minimum pressure

Type of Fault

The pump does not stop.

Cause

Remedy

Maximum pressure too high

Set the maximum pressure at lower
values

Type of Fault

The pump vibrates or makes too much noise while operating

Cause

Remedy

Flow rate too high

reduce flow rate

Cavitation

Contact Ebara

Irregular piping

adjust the pipe configuration

Noisy bearing

Contact Ebara

Foreign bodies rubbing

remove the foreign bodies against the
motor fan

Ebara Fluid Handling

1651 Cedar Line Drive • rock Hill, SC 29730
(t) 803 327 5005 • (f) 803 327 5097

www.pumpsebara.com

© 2005 Ebara International Corporation

EFH JEU1003 0112