EBARA JEU User Manual
Page 11

Ebara
Fluid Handling
www.pumpsebara.com
11
(803) 327-5005 • (803) 327-5097
fax
rev. 01/12
Ebara Self Priming Jet Pumps
JEU
Troubleshooting
Type of Fault
The pump does not work (the motor does not turn over).
Cause
Remedy
No electric power
Check the contactor on the electric line
Plug not inserted
Check power connection to the line
automatic switch has tripped
reset the switch and check the cause
Thermal protection has tripped
This resets automatically
(single phase)
(single phase only)
Protection fuses are burnt out
replace the fuses with others of the
(three phase)
(three phase)
Incorrect electric connection
Check terminal board and electric panel
Faulty motor or capacitor
Contact the nearest distributor
Damaged bearing (noisy)
Contact the nearest distributor
Type of Fault
The pump does not work (the motor does not turn over).
Cause
Remedy
Voltage drop on the power line
Clogged filter at end of suction
Dismantle and clean the filter
Foot valve blocked
Clean the valve and check its operation
No water in the pump
Fill the pump (page 9)
Pressure too low
Choke the delivery gate valve
Type of Fault
The pump works at a low flow rate.
Cause
Remedy
Foot valve partly clogged
Clean the valve and check its operation
Water level too low
Switch off the pump or immerse the foot valve
Wrong direction of rotation
Check the direction of rotation
(three phase only, page 9)
Wrong supply voltage
Supply the pump with the correct voltage
as indicated on the data plate.
Leaking pipes
Check the connections
Pressure too high
Check the system
Type of Fault
The pump stops after brief periods of operation (tripping of the thermal protection).
Cause
Remedy
Liquid temperature too high
The temperature exceeds the technical
limits of the pump
Internal defect
Contact the nearest distributor