JEU

Troubleshooting
Type of Fault

The pump does not work (the motor does not turn over).

Cause

Remedy

No electric power

Check the contactor on the electric line

Plug not inserted

Check power connection to the line

automatic switch has tripped

reset the switch and check the cause

Thermal protection has tripped

This resets automatically

(single phase)

(single phase only)

Protection fuses are burnt out

replace the fuses with others of the

(three phase)

(three phase)

Incorrect electric connection

Check terminal board and electric panel

Faulty motor or capacitor

Contact the nearest distributor

Damaged bearing (noisy)

Contact the nearest distributor

Type of Fault

The pump does not work (the motor does not turn over).

Cause

Remedy

Voltage drop on the power line
Clogged filter at end of suction

Dismantle and clean the filter

Foot valve blocked

Clean the valve and check its operation

No water in the pump

Fill the pump (page 9)

Pressure too low

Choke the delivery gate valve

Type of Fault

The pump works at a low flow rate.

Cause

Remedy

Foot valve partly clogged

Clean the valve and check its operation

Water level too low

Switch off the pump or immerse the foot valve

Wrong direction of rotation

Check the direction of rotation

(three phase only, page 9)

Wrong supply voltage

Supply the pump with the correct voltage

as indicated on the data plate.

Leaking pipes

Check the connections

Pressure too high

Check the system

Type of Fault

The pump stops after brief periods of operation (tripping of the thermal protection).

Cause

Remedy

Liquid temperature too high

The temperature exceeds the technical

limits of the pump

Internal defect

Contact the nearest distributor