Dlfu/dlfmu/dlkfu/dlkfmu – EBARA DLKFMU User Manual
Page 18

Ebara Submersible Sewage Pumps
DLFU/DLFMU/DLKFU/DLKFMU
Operating, Installation, and Maintenance
Ebara
Fluid Handling
www.pumpsebara.com
18
(803) 327-5005 • (803) 327-5097
fax
rev. 04/14
Leakage Detector
1. Construction:
Each switch has a magnet-containing float which senses the liquid level and magnetically actuates a dry reed switch
encapsulated within a stem. The switch opens on rise of liquid.
2. Specifications
• apply to 2 to 10HP
breaking Capacity
: aC50Va, DC50W
Max. breaking Current
: aC0.5a, DC0.5a
Max. Operating Voltage
: aC300V, DC300V
2.
• apply to 15 to 60HP
breaking Capacity
: aC12Va, DC10W
Max. breaking Current
: aC0.6a, DC0.5a
Max. Operating Voltage
: aC200V, DC200V
Lead Wire
Float Body
(304 S.S.)
Float
(304 S.S.)
Stopper
(304 S.S.)
Lead Wire
Float Body
(Polypropylene)
Float
(Polypropylene)
Stopper
(316 S.S.)
Open
Close
Close
Open