beautypg.com

Delivery checks, Specifications – EBARA DMLEU User Manual

Page 3

background image

Ebara Submersible Single Channel Sewage Pumps

DMLEU

Operating, Installation and Maintenance

Ebara

Fluid Handling

www.pumpsebara.com

3

(803) 327-5005 • (803) 327-5097

(fax)

rev. 01/13

Delivery Checks

When your pump is delivered, check the following items immediately.

1. Pump and accessories

a.) Confirm that no damage has occurred during transportation.
b.) Confirm that all items have been delivered.

2. Nameplate

a.) The basic specifications of the pump are listed on the nameplate. read the pump nameplate to confirm

that the pump you received matches the specifications that you ordered.

Fig. 1 – Pump Nameplate

Specifications

Item

Liquid handled

Type
Temperature

Solids Capacity

Discharge size (in.)
Solid size (in.)

Materials

Impeller
Phase
Hz

Motor

Voltage
Starting Method

Protector

Mechanical Seal Lubricants
Maximum water depth
Installation

Specifications

Waste water
0 - 40° C
3, 4, 6
3
Cast iron
Three Phase
60 Hz
208/230 or 460 VAC
2.2kW : Direct start
3.7 ~ 22kW : Star-Delta start
2.2kW : Auto-cut
3.7 ~ 22kW : Thermal Protector
Turbine oil ISO VG32
65 ft.
with Quick Discharge Connector or Floor mounted