beautypg.com

Specifications – EBARA CLU User Manual

Page 3

background image

EBARA Submersible Sewage Pumps

DLU / DLMU

Operating, Installation, and Maintenance

EBARA

Fluid Handling

www.pumpsebara.com

3

(t) 803 327-5005 • (f) 803 327-5097

rev. 01/10

Contents

Section

Page

Safety Information and Introduction ......................................................................................3
Specifications ........................................................................................................................3
Pump Checks ........................................................................................................................4
Installation ..............................................................................................................................4
Operation................................................................................................................................9
Maintenance and Service ....................................................................................................10
Sectional View ......................................................................................................................12
Warranty ................................................................................................................................14

Design of this EBARA pump is based on superior engineering and long experience. To prevent trouble and provide satisfactory operation and
long life, it is important to understand the EBARA pump thoroughly by careful study of this manual. If any questions arise regarding this manual,
please direct them to EBARA INTERNATIONAL CORPORATION.

Check the nameplate for your pump's head (HEAD), discharge volume (CAPACITY), speed (SPEED), motor voltage and current.
Other specifications are noted in the chart below.

Specifications

WARNING

Before handling this pump, always disconnect the power first. Do not use sparkable electrical devices or flames
in a septic (gaseous) or possible septic sump.

Do not work under heavy suspended object unless there is a positive support under it to stop its fall in event of
sling or hoist failure. Disregard of this warning could result in personal injury.

This pump should only be serviced by qualified or factory trained personnel.

CAUTION

This instruction manual includes necessary items for installation, operation and maintenance. Read this manual carefully to
ensure correct installation, operation and maintenance.

Be sure to keep this instruction manual on hand for future reference.

CAUTION

Be careful not to exceed the given specifications in the use of your products.

Item

Specifications

Type

Sewage, waste water, miscellaneous drain water

Liquid handled

Temperature

Motor: 1/2 - 5HP: 32 - 122

••

F

Motor: 1/2 - 5HP: 32 - 104

••

F

Casing

Cast iron

Materials

Impeller

Cast iron

Shaft

403 stainless steel

Motor type

Air filled submersible motor

Shaft seal lubrication oil

Turbine No. 32 ISO VG - 32

Maximum water depth

65 ft

Installation

with Quick Discharge Connector or floor mounted