D-series, Dimensions, Application – Delta Controls D-Series TDSST User Manual

Page 2: Measuring ranges

background image

www.delta-controls.com

D-Series

Models: S-T

Dimensions

Version

Diaphragm

diameter

Dm

Contact face

diameter

d1

Diameter
of bolt
circle K

External

diameter

D

Thick-

ness

d

Diameter

of holes

L

Number

of

holes

Tube

length

T

DN50 PN40
2’’ANSI 150

48
48

102

92

125

120,5

165
150

22
20

18
20

4
4

DN80 PN40
3’’ ANSI 150

75
75

138
127

160

152,5

200
190

24
24

18
20

8
4

50, 100

150, 200

DN100 PN40
4’’ANSI 150

88
89

162
158

190

190,5

235
230

24
24

22
20

8
8

50, 100

150

The diaphragm seal is a pressure transmitting, diaphragm-type device. The pressure signal is sent to the cooperating
pressure measuring device (pressure transmitter, pressure gauge) through manometric liquid filling the space between the
separating diaphragm of the seal and the pressure measuring device. The diaphragm seal task is to isolate the pressure
measuring device from damaging impacts caused by either medium or installation:

s

Low or high temperature, increased viscosity, and impurities

s

Tendency of crystallisation on the tank walls

s

Vibrations of the installation (remote diaphragm seal)

The flanged diaphragm seal with extended diaphragm is typically applies to measure the pressure or level of the media in a
multi-walled tank, where the separating diaphragm should be placed close to the inner wall of the tank.

Application

Recommended minimum measuring range (bar)

depending on the type of the set: pressure measuring device - diaphragm seal

Pressure

measuring device

Seal type

Diaphragm Seal Version

DN50 / 2’’

DN80 / 3’’

DN100 / 4’’

Smart

transmitters∗

direct

0.4

0.1

0.1

remote (2 m)

6

0.5

0.25

PCE-28

direct

0.1

0.1

0.1

remote (2 m)

2

0.5

2.5

Measuring Ranges

Additional absolute zero error resulting from ambient temperature fluctuations, depending

on the type of the set: pressure transmitter - diaphragm seal with a 100 mm of tube

Diaphragm seal type Absolute zero error per 10°C for the diaphragm seal

DN50 / 2’’

DN80 / 3’’

DN100 / 4’’

direct

2 mbar

0.6 mbar

0.4 mbar

remote (2 m capillary)

10 mbar

2

mbar

1

mbar

Temperature range of measured medium

Remote diaphragm seal

Direct dia phragm seal

Manometric liquid

Underpressure measurements

Overpressure measurements

high-temperature (DC)

-10...150°C

-10...315°C

-30...150°C

low-temperature (AK)

not recommended for measurement

of pressures < 0.5 bar ABS

-60...200°C

Note: When operating with an ambient temperature of <

-15°C, heating of capillaries filled with DC fluid is recommended.

An additional zero error, resulting from
temperature fluctuations in a medium,
depends on the temperature gradient in the
oil-based diaphragm sealing system. The error
value is, in any case, significantly smaller than
the error value shown in the table.


Maximum pressure for PN40 – 40 bar
Maximum pressure for ANSI 150 – 150 psi
Material of diaphragm, tube and flange
316Lss

Special versions

Other standards DIN and ANSI
Direct diaphragm seal for medium temp. over 150°C
Others

Important:
- contact face in diaphragram seal DN50 have a milled slot for a gasket (acc. to DIN 2512 FormN). Version without any
slot available on request. (acc. to DIN 2526 FormE)
- standard outlet of capillary from flange:
direct mounted diaphragm seal - axial
remote mounted diaphragm seal - radial