beautypg.com

Options for every application, Leed categories satisfi ed by the ugw system – ClimaCool UGW Optimized Quiet Screw User Manual

Page 3

background image

Shell and Tube Condenser

Factory installed

cleanable shell and tube condenser with enhanced
copper tube geometry. Provides removable, epoxy
coated, water plates to facilitate cleaning.

Motorized or Manual Water Isolation

Valves and Flush Ports

Factory installed

water isolation valves and fl ush ports provide
isolation to the module for maintenance and
cleaning of evaporator and condenser heat
exchangers while adjacent modules continue
normal operation. Both motorized and manual
valves include standard ¾” fi ll and fl ush valves.

Condenser Water Head Pressure

Regulating Control

Factory installed

motorized condenser water valves provide head
pressure regulation for low entering condenser
water temperature applications (less than 60°F).

Hot Gas Bypass

Factory installed allowing unit

operation below the minimum step of unloading.

Soft Start

Factory installed to reduce voltage

starting for lower inrush current.

Water Header Bypass

A fi eld installed

water header bypass may be utilized to prevent
deadheading the pump.

Pressure Diff erential Flow Sensor

Field

installed to prevent operation of chiller without
suffi cient water fl ow to evaporator and condenser.

Automatic CS Series Strainer Package

Field installed high quality stainless steel fi ltration
systems with minimum 60 mesh stainless steel
screens. Available options include pressure
diff erential alarm and automatic time fl ush.

Manual Strainers

Field installed to increase

effi ciency and ensure long life of the equipment
with Y-style and Basket strainers of cast iron 200
psi or carbon 275 psi with 60 mesh stainless steel
screens. All strainers are fi eld installed external to
the chiller bank for ease of service.

LEED categories satisfi ed by the

UGW system:

Sustainable Sites and Building Re-Use

Compact design shrinks mechanical room and
building footprint. This also allows modules to fi t
through existing doors eliminating the need for
demolition and reconstruction.

Enhanced Commissioning and

Measurement and Verifi cation

CoolLogic Control System provides maximum
fl exibility with BAS interface.

Optimized Energy Performance

Exceeds ASHRAE 90.1 minimum effi ciency.

Enhanced Refrigerant Management

Micro charge of chlorine-free and non-ozone
depleting refrigerant.

Thermal Comfort

Precise required heating

and cooling ensures the highest comfort for
building occupants.

Options for every application.