beautypg.com

Certifications to atex 94/9/ce – CEMB USA TR-NC8 ATEX User Manual

Page 6

background image

6

Certifications to ATEX 94/9/CE

0722

II 1 G Ex ia IIC T5

0722

II 1 G Ex ia IIC T6

CESI 03 ATEX 095

Legend of nameplate safety data

Marking of conformity with the applicable

European directives

0722

Number of the Notified Body carrying out the

surveillance (CESI)

Marking of conformity with Directive 94/9/EEC

and relative technical standards

II

Equipment suitable for surface applications

(not for mining)

1

Equipment intended for use in areas in which
explosive atmospheres caused by mixtures of
air and gases, vapours, mists or air/dust
mixtures,

are

present

continuously,

frequently or for long periods, very high
level of protection.

Suitable for Zone 0

G

Protection for Gases, Vapours, Mists

Ex ia

Equipment belonging to category "ia" with

instrinsic safety for Zone 0

II C

Suitable for substances (gases) of group IIC,

also suitable for groups IIA and IIB

T5
T6

Temperature class T5 (surface temp.100°C)

Temperature class T6 (surface temp.85°C)

CESI 03 ATEX

095

Certificate identification:

• Name of the laboratory issuing the CE-

type-examination certificate

• 03 = year of issuing the certificate
• 095 = number of the certificate

Ta = 70°C (T5)
Ta = 60°C (T6)

Ambient temperature -20 to +70 °C
Ambient temperature -20 to +60 °C