Certifications to ATEX 94/9/CE
0722
II 1 G Ex ia IIC T5
0722
II 1 G Ex ia IIC T6
CESI 03 ATEX 095
Legend of nameplate safety data
Marking of conformity with the applicable
European directives
0722
Number of the Notified Body carrying out the
surveillance (CESI)
Marking of conformity with Directive 94/9/EEC
and relative technical standards
II
Equipment suitable for surface applications
(not for mining)
1
Equipment intended for use in areas in which
explosive atmospheres caused by mixtures of
air and gases, vapours, mists or air/dust
mixtures,
are
present
continuously,
frequently or for long periods, very high
level of protection.
Suitable for Zone 0
G
Protection for Gases, Vapours, Mists
Ex ia
Equipment belonging to category "ia" with
instrinsic safety for Zone 0
II C
Suitable for substances (gases) of group IIC,
also suitable for groups IIA and IIB
T5
T6
Temperature class T5 (surface temp.100°C)
Temperature class T6 (surface temp.85°C)
CESI 03 ATEX
095
Certificate identification:
• Name of the laboratory issuing the CE-
type-examination certificate
• 03 = year of issuing the certificate
• 095 = number of the certificate
Ta = 70°C (T5)
Ta = 60°C (T6)
Ambient temperature -20 to +70 °C