Ordering data

A B C D E F

TR-NC / 8 / / -- / / -- / /

A : Sensor thread

Code

Thread

0

M10 x 1 standard

1

3/8”- 24UNF

2

Special to defined

3

M8x1

4

¼”- 28UNF

N

Not threaded

B : Sensore lenght (L)

Code

Lenght mm

-

not necessary data

C : Connection total lenght (sensor + cable + extension cable L1)

Code

Lenght m

0

0.5 m

1

1.0 m

2

5.0 m

3

7.0 m

4

9.0 m

5

Special to defined

12

12.0 m

D : Extension cable lenght

Code

Lenght

-

not necessary data

E : Transmitter measuring range

Codice

Campo di misura

0

100 µm-pp

1

125 µm-pp

2

200 µm-pp

3

250 µm-pp

4

Speciale da definire

5

± 1 mm

6

± 0,75 mm

7

± 0,5 mm

8

1000 µm-pp

9

300 µm-pp

K

Phase

E : Certified versions

Code

Certificate type

0

Nothing

1T5

ATEX II 1 G Ex ia IIC T5

1T6

ATEX II 1 G Ex ia IIC T6

Example of an order

TR-NC/ 8 / 0 / - / 2 / - / 1 / 1

0 = Sensor thread M 10

- = not necessary data

- = not necessary data

1 = Measuring range 125 µm

2 = Connection total lenght = 5 m

1T5 = ATEX certification