CEMB USA TR–I ATEX User Manual
Page 3

3
Transversal sensitivity
•
< 5 %
Linearity
•
± 2% F.S. - 75 Hz
Outer casing
(see enclosed dwg.99564-P)
•
Stainless steel AISI 316L integrated transmitter body
•
Aluminium Atex certified housing ( ¾”14NPT threads)
Insulation
•
≥ 10
8
Ω between signal and box
Axis of application
•
any
Threads
•
¼”18NPT male
•
M8x1,25 male
Mounting torque
•
5÷10 Nm
Maintenance
•
none
Electrical connections
Bipolar schielded cable, section of the conductors:
•
2x1 mm²
until 200 m
•
2x1,5 mm²
until 400 m
•
2x2,5 mm²
until 800 m
Possible arrangements when placing the order
•
Measuring range
•
Type of thread connection
Reference standards:
.
EN 60079-0 (2009): Explosive atmosphere - General Rules
.
EN 60079-1 (2007): Explosive proof housings “d”
.
EN 60079-31 (2009): Equipments for combustible dust Part 31: protection by means of
housings “t”