beautypg.com

Certifications to atex 94/9/ce – CEMB USA TR-26 ATEX User Manual

Page 5

background image

5

Notes for identification:
The transmitter is constructed to be correctly used, according to the conditions set out by the
following table:

Certifications to ATEX 94/9/CE

0722

II 2 G Ex ia IIC T4

0722

II 2 G Ex ia IIC T5

0722

II 2 G Ex ia IIC T6

CESI 09 ATEX 045

Legend of nameplate safety data

Marking of conformity with the applicable European directives

0722

Number of the Notified Body carrying out the surveillance (CESI)

Marking of conformity with Directive 94/9/CE

and relative technical standards

II

Equipment suitable for surface applications (not for mining)

2

Equipment designed to environments in which explosive atmospheres
caused by gases, vapours, mists or mixtures of air and dust may occur, high
level of protection. Suitable for zone 1.

G

Protection for gases, vapours, mists.

Ex ia

Equipment belonging to category "ia" with instrinsic safety.

II C

Suitable for substances (gases) of group IIC,

also suitable for groups IIA and IIB

T4
T5
T6

Temperature class T4 (surface temperature 135°C)
Temperature class T5 (surface temperature 100°C)

Temperature class T6 (surface temperature 85°C)

CESI 09 ATEX 045

Certificate identification:

Name of the laboratory issuing the CE-type-examination certificate

09 = certificate issuing year

045 = certificate number

Ta = 120°C (T4)

Ta = 90°C (T5)
Ta = 75°C (T6)

Ambient temperature –50 to +120 °C

Ambient temperature –50 to +90 °C