CEMB USA TR-26 ATEX User Manual
Page 2
2
Composition
Integrated transmitter body, in AISI 316L stainless steel material.
Power supply
24 Vdc (10 to 35 Vdc) current loop 4 to 20 mA (two-wires)
Maximum load as per figure 2
External connections
MIL-C-5015, 2 poles connector (conductors max section 2,5 mm²)
Environmental use field
- 50°C to + 120°C
IP 65 EN 60529/10.91 standards
Measurement type
Omnidirectional seismic (absolute vibrations)
Dynamic field
± 18 g
Transversal sensitivity
< 5 %
Linearity
± 2% - 75 Hz
Dynamic performances
±3% / 10Hz-1kHz (See figure 1)
-3db / 1.5Hz – 2.5kHz
Insulation
10
8
between signal and container
Application axis
any
Process standard connections
M8x1,25
¼”-18NPT
¼’’-28UNF
Maintenance
none
Electrical connections
bipolar shielded cable, typical conductors section 2x1mm²
Possible prearrangements to the order
measuring field
fastening
ATEX certification type
Figure 1 – Frequency response [db]