Composition

Integrated transmitter body, in AISI 316L stainless steel material.

Power supply

24 Vdc (10 to 35 Vdc) current loop 4 to 20 mA (two-wires)

Maximum load as per figure 2

External connections

MIL-C-5015, 2 poles connector (conductors max section 2,5 mm²)

Environmental use field

- 50°C to + 120°C

IP 65 EN 60529/10.91 standards

Measurement type

Omnidirectional seismic (absolute vibrations)

Dynamic field

± 18 g

Transversal sensitivity

< 5 %

Linearity

± 2% - 75 Hz

Dynamic performances

±3% / 10Hz-1kHz (See figure 1)

-3db / 1.5Hz – 2.5kHz

Insulation

 10

8

 between signal and container

Application axis

any

Process standard connections

M8x1,25

¼”-18NPT

¼’’-28UNF

Maintenance

none

Electrical connections

bipolar shielded cable, typical conductors section 2x1mm²

Possible prearrangements to the order

measuring field

fastening

ATEX certification type

Figure 1 – Frequency response [db]