beautypg.com

Troubleshooting – Hunter 59133 96 HFC-96 User Manual

Page 19

background image

www.HunterFan.com

1.888.830.1326

M0096-01 • 07/23/14 • © Hunter Fan Company

19

Troubleshooting

Excessive wobbling

• Tighten all of the blade and

blade ring screws until they
are snug.

• Turn the power off, support

the fan carefully, and check
that the hanger ball is
properly seated.

Noisy Operation

• Tighten the blade and blade

ring screws until they are snug.

• Check to see if any of the

blades are cracked. If so, replace
all of the blades.

Fan doesn’t work

• Make sure power switch is on.

• Push the motor reversing switch

firmly left or right to ensure that
it is engaged.

• Check the circuit breaker to

ensure the power is turned on.

• Make sure the blades spin freely.

• Turn off power from the circuit

breaker, then loosen the canopy
and check all the connections
according to the wiring diagram
on page 10.

• Turn off power from the circuit

breaker, then ensure the wall
control is properly installed
according to the instructions on
pages 16-17.