Battery
WEIGH SCALE RETROFIT KIT
(Continued)
MOUNTING THE BATTERY BOX
On the rear side of the front, left leg of the grain cart (the
leg below the auger hinge), position the Battery Box
below and to the right of the grommet as shown.
Using the Battery Box as a template, mark and drill two
3/8” holes. Secure the Battery Box to the grain cart leg
using two 3/8” x 1” flange bolts and nuts provided. Attach
the end plate to the battery box using two 3/8” x 1” flange
bolts and nuts.
CONNECTING THE POWER CORD
To connect the Power Cord to the Indicator Box, attach the screw plug end of the Power Cord into the power
port of the Indicator Box. To connect to the battery, secure the Red Wire of the Power Cord to the Positive
Terminal of the battery and the Black Wire to the Negative Terminal. Be sure any additional wires provided by
the Power Cord are properly stored and secured.
Battery
Junction
Box
200
200
Because Weigh-Tronix
does not use a Junction
Box, there are three
ports on the Indicator
Box where each of the
weigh cords connect
directly, plus a port for
the Power Cord.
Digi-Star’s Indicator
Box has one port for the
Power Cord and one
port for the Junction
Box.
MOUNTING THE INDICATOR BOX
On the outside face of the front, left leg of the grain
cart (the leg below the auger hinge), position the
Indicator Box Mounting Plate above the grommet
so the Indicator Box is positioned as shown. Mark
and drill two 3/8” holes and secure the Digi-Star
mounting plate using two 3/8” x 1” Flange Bolts and
Nuts.
To secure the Weigh-Tronix mounting plate, mark
and drill four 1/4” holes and secure using four 1/4” x
3/4” bolts and nuts.
To secure the Indicator Box to the mounting plate,
simply slide the Indicator Box over the mounting
plate as necessary.
MOUNTING THE JUNCTION BOX
(for Digi-Star Systems Only)
On the inside face of the front, left leg ot the grain cart
(the leg below the auger hinge), position the Junction Box
below and to the left of the grommet as shown.
Using the Junction Box as a template, mark and drill four
holes for the #10 pan bolts. Secure the Junction Box to
the grain cart leg using the #10 pan bolts and nuts provided.
The junction box is used for Digi-Star Weigh Systems only. Connect the cords from the weigh spindles and
weigh bar into any of the ports on the Junction Box. Match and attach the colored wires to the color coordinated
post.
If a Weigh-Tronix System is used, the cords from both weigh spindles and weigh bar connect directly into the
bottom face of the Indicator Box, therefore no Junction Box is required. (See the Weigh-Tronix Indicator Box
below.)