Repair and assembly, Pilot valve removal, Tools needed – All-Flo A200-NAA-VVYV-000 2 Aluminum User Manual
Page 18

all-flo.com
18
PILOT VALVE REMOVAL
STEP 1
Using the screwdriver, remove
three “Phillips Pan Head Mach
Screw (#6-32-x 3/8”)” in order to
remove the “Retaining Plate”.
Repeat for both sides of the pump.
STEP 2
Remove the “diaphragm rod” and
the “pilot sleeve assembly” from
the “Intermediate”.
TOOLS NEEDED
1) One Screwdriver, Phillips
2) Two Wrenches, 1/2 Inch
The chambers do not need to be
removed for this procedure.
The graphics show the inner
chambers removed for clarity.
WARNING
Prior to servicing the pump, ensure that the air and
fluid lines are closed and disconnected. While wearing personal
protective equipment, flush, drain and process liquid from the pump
in a safe manner.
STEP 3
Remove the “lip seal” and “end
spacer”.
STEP 4
Remove “o-rings” and “inner
spacer”.
REPAIR AND ASSEMBLY
STEP 5
Remove “pilot sleeve” from
diaphragm rod. The two piece rod
must be disassembled to remove
the “pilot sleeve”.
- A200-NAA-TTYT-000 2 Aluminum A200-NAA-SSPE-000 2 Aluminum A200-NAA-NNPN-000 2 Aluminum A200-NAA-GTPN-000 2 Aluminum A200-NAA-GGPN-000 2 Aluminum A200-BAA-VVYV-000 2 Aluminum A200-BAA-TTYT-000 2 Aluminum A200-BAA-SSPE-000 2 Aluminum A200-BAA-NNPN-000 2 Aluminum A200-BAA-GTPN-000 2 Aluminum A200-BAA-GGPN-000 2 Aluminum A200-EA3-VV3V-000 2 316 Stainless Steel A200-EA3-TT3T-000 2 316 Stainless Steel A200-EA3-SS3E-000 2 316 Stainless Steel A200-EA3-GG3N-000 2 316 Stainless Steel A200-CA3-VV3V-000 2 316 Stainless Steel A200-CA3-TT3T-000 2 316 Stainless Steel A200-CA3-SS3E-000 2 316 Stainless Steel A200-CA3-GG3N-000 2 316 Stainless Steel