beautypg.com

Fan motors – Schreiber Chillers 2500modify User Manual

Page 14

background image

2500AC

FAN MOTORS



SPECIFICATIONS:

H.P. 1 each – 3 per unit.

VOLTAGE - 460 3 phase

HZ-50-60

RPM 1725

OVERLOAD - Automatic, Internal

FRAME - LA56, ROT. CW from top of unit.

MTG - Rigid, Open Motor

CAT. NO. Leeson #111311

ROTATION: Motor can run either direction, clockwise (CW) or counter clockwise (CCW).
Note the given direction on unit. – We set at the above rotation.

FAN BLADE: 24" x 23

o

CW OR CCW – 3 each.


SAFETY: Avoid personal injury or equipment damage by disconnecting electrical power
before working on the motor. Make sure the power is off when checking each phase.

MAINTENANCE:

1.

There are no lubrication points, therefore, no lubrication is necessary.

2.

Make sure the blade runs in the correct rotation.

3.

Clean the outside of the fan motor as necessary.















14