Connections, Configuring inputs, Configuring outputs – MoTeC ESDL3 User Manual
Page 25: Configuring communications
MoTeC
Configuration
21
Connections
Configuring Inputs
1. On
the
Connections
menu, click Devices
2. Select the device (e.g. SDL3) and then click the Input pins tab
This will list all inputs available for this product
3. Select the input and click Channel (or double-click the input)
4. Assign a measurement channel to the input and click OK
5. The channel needs to be calibrated using one of two options:
Select Load Cal if a pre-defined calibration is available
OR
Double-click the input to enter a calibration
Other tasks:
• Change Cal – to change the calibration
• Spd Levels – only for speed inputs
• Settings – to set default
Configuring Outputs
1. On
the
Connections menu
, click Devices
2. Select device (e.g. SDL3) and then click the Output Pins tab to list all
outputs available for this product
3. Select the output and click Change (or double-click the output)
4. Select a mode to make appropriate settings available
5. Follow the directions on the screen and when all settings are done
click OK
Configuring Communications
1. On
the
Connections menu
, click Communications
2. Select an available communications section (CAN or RS232)
3. Click
Select
and choose one of the available communications
templates
Comms templates
Communication templates are available for most connected MoTeC devices.
When MoTeC releases new products, new communication templates will also
be released. These will be incorporated in the latest software versions. See