Specifications, Motec – MoTeC AFM1 User Manual
Page 5

MoTeC
Specifications
1
Specifications
Meter
Operating Voltage Range
7 to 16 V DC
Operating Current
0.3 A Max. (Excluding Sensor)
Reverse Voltage
- 24 V DC Max.
Transient Protection
10 Joules (100A / 10ms) (Clamping Voltage
24V)
Operating Temperature
0 to 60 deg C
Operating Humidity
0 to 80 % Non Condensing
Measurement Range
0.75 to 1.60 Lambda
Measurement Accuracy
± 1.5% 0.75 to 1.05 Lambda
± 2.5% 1.06 to 1.25 Lambda
± 5.0% 1.26 to 1.60 Lambda
Display Update Rate
3.5 Times per second
Response Time
< 150 msec (To 63 % of Final Reading)
Weight 575
g
Dimensions
142 x 48 x 96 mm (WxHxD)
Meter Analog Output
Output Type
Isolated (Floating)
Output Isolation
400 V DC Max.
Output Voltage Range
0 to 5 V DC Max. ( Dependant on Range
Selection )
Output Current
1 mA Max.
Response Time
100 ms 0.75 to 0.95 Lambda
150 ms 0.96 to 1.05 Lambda
50 ms 1.06 to 1.60 Lambda
(To 63 % of Final Reading)