BatteryMINDer 12248-AA User Manual
Page 30

Rev. C-020907
P/N VDC12248AA-MNL
BatteryMINDer
®
Model 12248-AA
Page 0
DETAILED SPECIFICATIONS - VDC Model No. 12248-AA (con’t.)
•
Charging Output Control Characteristics
•
Charging Flow : Battery condition detect>Soft Start Charge>Bulk Charge>Absorption
Charge>Sulphate Check>Float Charge
•
Soft Start Charging Activity conditions: Battery Voltage is over Vdc and less than 10.5Vdc
(the charger will start at 2A mode & Gel mode automatically)
•
Soft Start Charging output current control: (2A / 4A / 8A mode) 0.5 / 1 / 2 ±0.25 Adc
•
Soft Start Charging Time Limited: (Stop charge If battery cannot be charged over 10.5V after
6 hrs, Error LED flash indicated) 6 ±0.25 Hours
•
Bulk Charging Activity conditions: Battery Voltage is over 10.5Vdc
(the charger will start at
2A mode & Gel mode automatically)
•
Bulk Charging Current control at 2A mode: (Selected by pressing Charge Rate Button)
2 +0.5 / -0 Adc
•
Bulk Charging Current control at 4A mode: (Selected by pressing Charge Rate Button)
4 +0.40 / -0 Adc
•
Bulk Charging Current control at 8A mode: (Selected by pressing Charge Rate Button)
8 +0.45 / -0 Adc
•
Max. rated output voltage and current: 1.0V at 8Adc 14.6V at 6.5Adc
•
Bulk Charging Time Limited: (Stops charge If battery cannot be charged reach 14.1/14.4/14.1V
after 20 hrs, error LED flash indicated) 20 ±1 Hours