BatteryMINDer

®

Aviation-Adjusted Models 12248-AA-S2, S3 & S5

Rev. C-071213

Page 13

P/N VDC12248-AA-Sx-MNL

5.

Charger will automatically start within 15 - 30 seconds.

The Charge

– Float LED Indicator will light

GREEN. The charger will now begin

charging by first checking the battery to determine its voltage and

ability to accept a charge. Should the battery not have a normal

fully discharged voltage (10.5V minimum) the unit will begin charging

in the “Soft-Start” mode to determine if the battery can be safely

charged. If it cannot, the Power On – Error LED will flash

RED and

charging will be stopped. Battery should be carefully checked under

a load by a qualified person before further attempting to charge it.

Note

: If the battery does not have a minimum no

load OCV (Open Circuit Voltage) of 3 volts, the ERROR

LED will light RED and charger will reject battery.

No further effort should be made to charge this battery with this

charger or any charger. Discard this battery, unless it has just

been subjected to a long period of continuous discharge under

a load such as can occur with leaving lights on or cranking an

engine excessively. Allow such a battery to “Rest” for several

hours (overnight if possible) before determining if it is defective.

Be very suspicious of any 12-V battery that does not have at least 11

Volts (OCV) before it is recharged. It may well be seriously damaged

and unsafe for any type of use or recharge. The unit’s Battery

Condition Indication

LED will help you

determine if battery

is less than 11 Volts

(

YELLOW) or greater

than 11 Volts (

GREEN).

6.

After battery has

been fully charged, the

GREEN Charge-Float

LED Indicator will begin

blinking. It will continue

to blink indefinitely,

unless unit is disconnected from battery. Should battery be unable

to be fully charged, the LED will not blink and the

RED Error LED

will blink. Battery may not be able to be fully charged, may be too

OCV=Open Circuit No Load Voltage

OCV - “Rested”

Voltage

Full Capacity

Percentage

12.9 - 13.1 Volts

100%

12.6 - 12.9 Volts

75%

12.4 - 12.6 Volts

50%

12.2 - 12.4 Volts

25%

12.0 - 12.2 Volts

0%

<11 Volts

shorted