Batteryminder, Model scc180 – BatteryMINDer SCC180 User Manual
Page 7

BatteryMINDer
®
Model SCC180
Rev. B-073108
Page 7
P/N VDCSCC180-MNL
If only the
RED
and
YELLOW
LEDs light your battery is “fair” = 11.8
– 12.7-volts
If only the
RED
LED lights your battery is in “poor” condition (11.2 – 11.7-
volts. Battery needs to be desulphated fully before it can be further
evaluated to determine if it can be returned to “good” condition.
WHEN NO LEDs are lit, battery can be considered “DEAD”, unlikely
able to be restored. AGAIN, this can only be accurately determined if
you have correctly allowed your battery to “rest”* after first having fully
charged it as indicated above.
IMPORTANT NOTE: Fused lead (located on positive lead of battery
connector): ATC-3 blade type 3 amp rated. DO NOT ATTEMPT TO
BYPASS OR REPLACE WITH HIGHER RATED FUSE; SERIOUS
DAMAGE WILL OCCUR.