beautypg.com

Batteryminder, Model scc180 – BatteryMINDer SCC180 User Manual

Page 10

background image

BatteryMINDer

®

Model SCC180

Rev. B-073108

Page 10

P/N VDCSCC180-MNL

Wet Cell Charge And Float Voltages at Various Temperature Ranges

Temp

ºF

Optimum

Temp

ºC

Charge

Float

10

12.5

12.6

49

110 – 120

13.6

1.7

44 – 48

100 -10

13.8

1.

38 – 43

90 – 99

14.0

13.1

32 – 37

80 – 89

14.2

13.3

27 – 31

70 – 79

14.4

13.5

21 – 26

60 – 69

14.6

13.7

16 - 20

50 – 59

14.8

13.

10 - 15

40 – 49

15.0

14.1

5 - 9

3

15.2

14.3

4

The accuracy of the above voltages should be +/- 0.2 volts.

Gel Charge and Float Voltages at Various Temperature Ranges**

Temp

°F

Charge

Float

Temp

°C

Optimum

Maximum

Optimum

Maximum

10

13.00

13.30

1.80

13.00

49

110 – 120

13.0

13.50

1.0

13.0

44 – 48

100 -10

13.30

13.60

13.00

13.30

38 – 43

90 – 99

13.40

13.70

13.10

13.40

32 – 37

80 – 89

13.50

13.80

13.0

13.50

27 – 31

70 – 79

13.70

14.00

13.40

13.70

21 – 26

60 – 69

13.85

14.15

13.55

13.85

16 - 20

50 – 59

14.00

14.30

13.70

14.00

10 - 15

40 – 49

14.20

14.50

13.0

14.20

5 - 9

3

14.50

14.80

14.20

14.50

4

**East Penn Technical Manual of Valve-Regulated Lead-Acid (VRLA) Gelled Electrolyte (gel), E.P.M. Form No.
0139 Rev. 3/04
Note: This chart shows the Charge and Float voltage ranges v. temperature for sealed 24-Volt Gel type batter-
ies. Values will differ for sealed AGM, Flooded (filler cap) or maintenance-free types Manifold cover(s).