Quick Connect Instructions

Place the Positive (

RED

) clip on the positive battery terminal.

Place the Negative (

Black) clip on the negative battery terminal.

Plug in the BatteryMINDer.

Power and Battery Connection light should be

GREEN

. Indicator

will come on showing state of battery charge and present charging

stage.

Charging Stages

Soft Start is used if a battery’s voltage is under 10.5V when

charging begins. It uses a low constant current to slowly bring

up voltage. This prepares a weak or neglected battery for the

Constant Current stage.

Constant Current (sometimes called Bulk) is the main charging

stage. The charger puts out a constant current of 2A, its full power.

Battery voltage rises until the battery reaches the optimal charging

voltage CV* (See Voltage Table).

Constant Voltage (sometimes called Absorption) is the second

charging stage. The charger regulates the current given to the

battery to maintain a constant voltage CV* (See Voltage Table).

As the battery nears a full charge, the current needed to maintain

this voltage decreases. Once the current falls below 0.5A (0.1A for

2012-AGM) the stage is complete.

Battery Test is administered by reading your battery voltage

while resting the battery for 10 minutes. A voltage of under 12.5V

indicates a weak battery, under 11.5V indicates a shorted cell. The

battery is tested at completion of the

Constant Voltage stage, and

every 12 hours while in

Float

1.

2.

3.

4.

Load Light Off

Load Light

Soft Start

0.5 A

Float

(Battery < 11V)

2.0 A

Constant

Current

2.0 A

Float

(Battery < 12V)

2.0 A

Constant

Voltage

CV* (See

Voltage Table)

Float

(Battery < 13V)

2.0 A

Float (Charge

Complete)

FV* (See

Voltage Table)

Float

(Battery > 13V)

2.0 A