P/N VDC2000-MNL

Desulfation light flashes

BLUE

any time the unit is desulfating.

The BatteryMINDer desulfates any time it is outputting current.

Temperature Compensation light is

GREEN

if the temperature

is over 27°C/80°F,

BLUE

if the temperature is under 21°C/70°F.

BatteryMINDer Model 2012 includes an ambient temperature

sensor which allows it to vary the output voltage as necessary to

properly charge your battery (-0.025 V/°C). Batteries charged at

higher temperatures without compensation will overcharge and

may outgas. Batteries charged at lower temperatures without

compensation will undercharge allowing sulfation to build, possibly

leading to the battery freezing. By using temperature compensation,

the BatteryMINDer ensures your battery will never over or under

charge, even in extreme conditions.

Temperature

Compensation

50°C

/

122°F

-0.625 V

45°C

/

11°F

-0.500 V

40°C

/

104°F

-0.75 V

5°C

/

95°F

-0.250 V

0°C

/

86°F

-0.125 V

25°C

/

77°F

0.000 V

20°C

/

68°F

+0.125 V

15°C

/

59°F

+0.250 V

10°C

/

50°F

+0.75 V

5°C

/

41°F

+0.500 V

0°C

/

2°F

+0.625 V

-5°C

/

2°F

+0.750 V

-10°C

/

14°F

+1.000 V

-15°C

/

5°F

+1.125 V

-20°C

/

-4°F

+1.250 V

Consider using accessory ABS-248 “At the Battery Sensor” for more

accurate temperature compensation. It is highly recommended if your

battery is located in a different environment or compartment than your

charger.