CHARGING STAGES

Constant Power (sometimes called bulk) is the main charging stage. The unit

outputs its full power. Battery voltage rises until the battery reaches the trip

voltage (see table).

Float (sometimes called maintenance) is the unit’s long term stage. The unit is

designed to be left connected indefinitely. It will keep your battery fully charged,

ensuring no sulfate can form. The unit maintains the float voltage (see table)

using very little power as it actively monitors your battery and adjusts its output

several times a second.

ADDITIONAL FEATURES

Desulfation is the removal of sulfate build-up from your battery’s plates. It

occurs at all times the unit is connected.

Short Circuit, Spark and Reverse Polarity Protection prevent the unit from

having any output unless it is properly connected to your battery.

Temperature Protection shuts down the unit if operating temperature is

exceeded.

INDICATOR LIGHTS

On/Charging light is

RED

anytime the unit is plugged in to 120V AC Power.

Battery Condition light is

GREEN

when the unit it is correctly connected to

a battery. Battery Connection light is

FLASHING GREEN

when the unit is in

Float

Mode.

MAINTENANCE BUTTON

Press for Maintenance skips the Constant Power stage, putting the unit into

Float

Mode.

TROUBLESHOOTING

VDC Electronics Technical Support: (800) 379-5579 x206

Unit does not have an output unless connected to a battery. In order to

test the output using a meter, connect the meter to your battery. When you

connect the unit, you will see the voltage rise.

If the unit is not in float after 72 hours (per battery if charging multiple),

check to make sure your battery meets the minimum voltage (see table)

requirements.

Unit will not operate if battery is below the minimum voltage.

If there is a load on your battery, disconnect it and charge again.

If the problem persists, your battery may be shorted or badly sulfated, use the

“Press for Maintenance” button to override the charge stage and go directly

into float.

Badly sulfated batteries may need 2-4 weeks of float charging to show

results.